| @@ -1,7 +1,14 @@ |
| ### Statement |
| ### Statement |
| |
| |
| $11.3.25.$ [Insert the problem statement] |
| $11.3.25.$ |
| |
| |
| |
| There are two identical ideal transformers with the same transformation co- |
| |
| efficient of 1 : 3. The primary winding of one of them is connected in series |
| |
| with the secondary of the second, and the free ends of these windings are con- |
| |
| nected to the AC network with a voltage of 100 V. The secondary winding of |
| |
| the first transformer is connected in series with the primary winding of the |
| |
| second. Determine the amplitude of the AC voltage between the other ends |
| |
| of the windings. |
| ### Solution |
| ### Solution |
| |
| |
| For two identical ideal transformers with a 1:3 turns ratio, the no‑load current is not zero due to the finite magnetizing inductance. Let$ L_m$ be the magnetizing inductance referred to the primary of each transformer. |
| For two identical ideal transformers with a 1:3 turns ratio, the no‑load current is not zero due to the finite magnetizing inductance. Let$ L_m$ be the magnetizing inductance referred to the primary of each transformer. |
| | | |
| The input loop (100 V source) forces a current I through the series connection formed by the primary of the first transformer (P1) and the secondary of the second (S2). | | The input loop (100 V source) forces a current I through the series connection formed by the primary of the first transformer (P1) and the secondary of the second (S2). |
| | | |
| In transformer 1, the secondary S1 is open‑circuited, so the ideal primary current is zero and the entire current I flows through the magnetizing inductance $L_m$: | | In transformer 1, the secondary S1 is open‑circuited, so the ideal primary current is zero and the entire current I flows through the magnetizing inductance $L_m$: |
| | | |
| $V_{P1} = \mathrm{j}\omega L_m I$ | | $V_{P1} = \mathrm{j}\omega L_m I$ |
| | | |
| In transformer 2, the primary P2 is open; the secondary S2 carries I, and its magnetizing inductance referred to the secondary is $(3)^2L_m = 9L_m $so that | | In transformer 2, the primary P2 is open; the secondary S2 carries I, and its magnetizing inductance referred to the secondary is $(3)^2L_m = 9L_m $so that |
| | | |
| $V_{S2} = \mathrm{j}\omega (9L_m) I = 9\,V_{P1}$ | | $V_{S2} = \mathrm{j}\omega (9L_m) I = 9\,V_{P1}$ |
| | | |
| The source imposes $V_{P1} + V_{S2} = 100, so 10\,V_{P1} = 100 \Rightarrow V_{P1} = 10\ \text{V}$ | | The source imposes $V_{P1} + V_{S2} = 100, so 10\,V_{P1} = 100 \Rightarrow V_{P1} = 10\ \text{V}$ |
| | | |
| By the turns ratio of the first transformer, $V_{S1} = 3\,V_{P1} = 30\ \text{V}$ | | By the turns ratio of the first transformer, $V_{S1} = 3\,V_{P1} = 30\ \text{V}$ |
| In the second transformer,$ V_{P2} = V_{S2}/3 = 90/3 = 30\ \text{V}$ | | In the second transformer,$ V_{P2} = V_{S2}/3 = 90/3 = 30\ \text{V}$ |
| The output voltage between the free ends of S1 and P2 is the sum: | | The output voltage between the free ends of S1 and P2 is the sum: |
| | | |
| $V_{\text{out}} = V_{S1} + V_{P2} = 30 + 30 = 60\ \text{V}$ | | $V_{\text{out}} = V_{S1} + V_{P2} = 30 + 30 = 60\ \text{V}$ |
| | | |
| $\boxed{V_{\text{out}} = 60\ \text{V}}$ | | $\boxed{V_{\text{out}} = 60\ \text{V}}$ |
| | | |