When an alternating voltage is applied to a coil, the total flux generated is split into two identical paths, so that the other coil, placed in one of the branches, is only linked by half of the total flux.
In the first case, with$V_1 = 40\ \text{V}$on coil 1, a voltage$V_2 = 10\ \text{V}$appears on coil 2. The voltage ratio is
from which it follows that $N_2 = N_1/2$ (coil 2 has half the number of turns as coil 1).
When the connection is reversed and $V_2' = 10\ \text{V}$ is applied to coil 2, the generated flux divides just as before. Coil 1 is in one branch and receives half of the total flux. The voltage induced in it is